CPS Trifase

Generatore mono/trifase compatto non isolato e adatto per sistemi di collaudo monofase/trifase.

Scheda tecnica


Zoom image

Zoom image
Code9911077099110780
NameCPS 4KVA/8KVA (5KVA)CPS 7,5KVA/15KVA
Power Countinous mode5KVA10KVA
Power Inrush mode4KVA/8KVA7.5KVA/15KVA
Output1phase / 3phase1phase / 3phase
CharacteristicNot IsolatedNot Isolated
VOLTAGERange150V/300V(4)150V/300V(4)
Accuracy<0.5% f.s.<0.5% f.s.
Distortion<0.6%<0.6%
Stability of the output voltage<0.1% f.s.<0.1% f.s.
Recovery time of the waveform<10ms<10ms
Maximum Compensated drop5% s.v.5% s.v.
Recovery-time of drop on wires<200ms.<200ms.
Output voltage resolution0.025% f.s.0.025% f.s.
Inrush function
(Max current)
1PHRMS continuous (2) 150V26,7 A50 A
RMS continuous (2) 300V13,3 A25 A
Inrush Current (3 seconds)(2) 150V53,4 A100 A
Inrush Current (3 seconds)(2) 300V26,6 A50 A
3PHRMS continuous (2) 150V8,9 A16,7 A
RMS continuous (2) 300V4,4 A8,3 A
Inrush Current (3 seconds)(2) 150V17,8 A33,4 A
Inrush Current (3 seconds)(2) 300V8,8 A16,6 A
Countinous function
(Max current)
1PHRMS continuous (2) 150V33,2 A66,4 A
RMS continuous (2) 300V16,6 A33,2 A
3PHRMS continuous (2) 150V11,1 A22,2 A
RMS continuous (2) 300V5,5 A11,1 A
FREQUENCYOutput frequency range10Hz(5) – 80Hz10Hz(5) – 80Hz
Range of synchronization45Hz – 65Hz45Hz – 65Hz
Frequency resolution0.02Hz0.02Hz
Frequency precision100ppm100ppm
SUPPLYInput supply400Vac ± 10% 3PH+N400Vac ± 10% 3PH+N
Maximum Input current12A/24A neutral18A/41A neutral
Input Frequency47Hz-63Hz47Hz-63Hz
OTHERSize (H : W : D)281 : 471 : 5131150 :585 : 600
Weight54Kg180Kg
ProtectionsOVP;UVP;OTPOVP;UVP;OTP
Operation Temperature Range0-35°C0-35°C
RS232YESYES
RS485OPTIONOPTION
LANOPTIONOPTION
Remote programPS InterfacePS Interface
Driver LabVIEWPS Driver rev. 1PS Driver rev. 1
Manual62000585_it_en 
CPS Parameters
62000585_it_en 
CPS Parameters
BrochureCPS 5 KVACPS 10 KVA
Communication protocol
manuals
Elettrotest
SCPI
Elettrotest
SCPI
Declaration of conformityUE
UKCA
UE
UKCA
FILTERSingle/Three phase
Not isolated
Double range
Rack version available
OVP = Over voltage protection
UVP = Under voltage protection
OTP = Over temperature protection
f.s. = Full scale
(2) With Resistive load
(4) Other range on request
(5) It is possible on remote interface to set 10Hz but you must
decrease the maximum voltage

Zoom image

Zoom image
Code9911079099110800
NameCPS 15KVA/30KVA (20KVA)CPS 30KVA/60KVA (40KVA)
Power Countinous mode20KVA40KVA
Power Inrush mode15KVA/30KVA30KVA/60KVA
Output1phase / 3phase1phase / 3phase
CharacteristicNot IsolatedNot Isolated
VOLTAGERange150V/300V(4)150V/300V(4)
Accuracy<0.5% f.s.<0.5% f.s.
Distortion<0.6%<0.6%
Stability of the output voltage<0.1% f.s.<0.1% f.s.
Recovery time of the waveform<10ms<10ms
Maximum Compensated drop5% s.v.5% s.v.
Recovery-time of drop on wires<200ms.<200ms.
Output voltage resolution0.025% f.s.0.025% f.s.
Inrush function
(Max current)
1PHRMS continuous (2) 150V100 A200 A
RMS continuous (2) 300V50 A100 A
Inrush Current (3 seconds)(2) 150V200 A400 A
Inrush Current (3 seconds)(2) 300V100 A200 A
3PHRMS continuous (2) 150V33,4 A66,8 A
RMS continuous (2) 300V16,7 A33,4 A
Inrush Current (3 seconds)(2) 150V66,8 A134 A
Inrush Current (3 seconds)(2) 300V33,4 A66,8 A
Countinous function
(Max current)
1PHRMS continuous (2) 150V133 A266 A
RMS continuous (2) 300V66,4 A133 A
3PHRMS continuous (2) 150V44,4 A88,9 A
RMS continuous (2) 300V22 A44 A
FREQUENCYOutput frequency range10Hz(5) – 80Hz10Hz(5) – 80Hz
Range of synchronization45Hz – 65Hz45Hz – 65Hz
Frequency resolution0.02Hz0.02Hz
Frequency precision100ppm100ppm
SUPPLYInput supply400Vac ± 10% 3PH+N400Vac ± 10% 3PH+N
Maximum Input current34A/64A neutral60A/125A neutral
Input Frequency47Hz-63Hz47Hz-63Hz
OTHERSize (H : W : D)1410 :585 : 6001410 :585 : 600
Weight300Kg450Kg
ProtectionsOVP;UVP;OTPOVP;UVP;OTP
Operation Temperature Range0-35°C0-35°C
RS232YESYES
RS485OPTIONOPTION
LANOPTIONOPTION
Remote programPS InterfacePS Interface
Driver LabviewPS Driver rev. 1PS Driver rev. 1
Manual62000585_it_en
CPS Parameters
62000585_it_en 
CPS Parameters
BrochureCPS 20 KVACPS 40 KVA
Communication protocol
manuals
Elettrotest
SCPI
Elettrotest
SCPI
Declaration of conformityUE
UKCA
UE
UKCA
FILTERSingle/Three phase
Not isolated
Double range
Rack version available
OVP = Over voltage protection
UVP = Under voltage protection
OTP = Over temperature protection
f.s. = Full scale
(2) With Resistive load
(4) Other range on request
(5) It is possible on remote interface to set 10Hz but you must
decrease the maximum voltage

Prodotti che potrebbero interessarti

RPS Monofase

Generatore monofase combinabile a rack per diverse configurazioni in sistemi di collaudo.

CPS Monofase

Generatore monofase VA compatto, non isolato e adatto per sistemi di collaudo monofasi.

TPS Monofase

Generatore monofase compatto, non isolato e adatto per carichi molto distorcenti con doppio range di uscita.

TPS Monofase con display

Generatori di tensione AC/DC monofase, programmabile in tensione e frequenza, progettati per generare una tensione sinusoidale e continua dalle elevate caratteristiche di purezza, stabilità e precisione.

RPS Trifase

Generatore trifase 20KVA combinabile a rack per diverse configurazioni in sistemi di collaudo.

TPS Trifase

Generatore mono/trifase isolato e adatto per carichi molto distorcenti mantenendo una tensione pura, precisa e stabile.

XPS Trifase

Serie di Programmable Power Source (denominata serie XPS), in grado di fornire tensione DC e tensione AC da 10 Hz a 1kHz con elevata caratteristica di purezza, stabilità e precisione.

HPS Trifase

Generatore trifase isolato e adatto per sistemi di grossa potenza con elevati spunti.