RPS Trifase

Generatore trifase 20KVA combinabile a rack per diverse configurazioni in sistemi di collaudo.

Scheda tecnica


Zoom image
Code99113553
NameRPS 15K/30S (20KVA)
Power Countinous mode20 KVA
Power Inrush mode15KVA / 30KVA
OutputExternal transformer necessary
VOLTAGERange150V/300V(4)
Accuracy<0.5% f.s.
Distortion<0.6%
Stability of the output voltage<0.1% f.s.
Recovery time of the waveform<10ms
Maximum Compensated drop5% s.v.
Recovery-time of drop on wires<200ms
Output voltage resolution0.025% f.s.
Inrush function
(Max current)
1PHRMS continuous (2) 150V101 A
RMS continuous (2) 300V50 A
Inrush Current (3 seconds)(2) 150V203 A
Inrush Current (3 seconds)(2) 300V102 A
3PHRMS continuous (2) 150V34 A
RMS continuous (2) 300V17 A
Inrush Current (3 seconds)(2) 150V68 A
Inrush Current (3 seconds)(2) 300V34 A
Countinous function
(Max current)
1PHRMS continuous (2) 150V133 A
RMS continuous (2) 300V67 A
3PHRMS continuous (2) 150V45 A
RMS continuous (2) 300V22 A
FREQUENCYOutput frequency range50Hz(5) – 80Hz
Range of synchronization45Hz – 65Hz
Frequency resolution0.02Hz
Frequency precision100ppm
SUPPLYInput supply400Vac±10% 3PH
Maximum Input current50A
Input Frequency47Hz-63Hz
OTHERSize (H : W : D)8U : 84TE : 500
Weight50Kg
ProtectionsOVP;UVP;OTP
Operation Temperature Range0-35°C
RS232YES
RS485OPTION
LANOPTION
Firmware with SCPIOPTION
Remote programPS Interface
Driver LabVIEWPS Driver rev. 1
Manual62000587
BrochureRPS 20K 15K30S
Communication protocol
manuals
Elettrotest
Declaration of conformityUE
UKCA
Single/Three phase
Double range
Rack version available
OVP = Over voltage protection
UVP = Under voltage protection
OTP = Over temperature protection
f.s. = Full scale
(2) With Resistive load
(4) Other range on request
(5) It is possible on remote interface to set 10Hz but you must
decrease the maximum voltage
(6) It is possible to use in single phase mode but with 1/3 of nominal
power. It is possible asymmetrical output current

Prodotti che potrebbero interessarti

RPS Monofase

Generatore monofase combinabile a rack per diverse configurazioni in sistemi di collaudo.

CPS Monofase

Generatore monofase VA compatto, non isolato e adatto per sistemi di collaudo monofasi.

TPS Monofase

Generatore monofase compatto, non isolato e adatto per carichi molto distorcenti con doppio range di uscita.

TPS Monofase con display

Generatori di tensione AC/DC monofase, programmabile in tensione e frequenza, progettati per generare una tensione sinusoidale e continua dalle elevate caratteristiche di purezza, stabilità e precisione.

CPS Trifase

Generatore mono/trifase compatto non isolato e adatto per sistemi di collaudo monofase/trifase.

TPS Trifase

Generatore mono/trifase isolato e adatto per carichi molto distorcenti mantenendo una tensione pura, precisa e stabile.

XPS Trifase

Serie di Programmable Power Source (denominata serie XPS), in grado di fornire tensione DC e tensione AC da 10 Hz a 1kHz con elevata caratteristica di purezza, stabilità e precisione.

HPS Trifase

Generatore trifase isolato e adatto per sistemi di grossa potenza con elevati spunti.